Visionstar XCT350 CT Scan

$255,000.00

+ Free Shipping

CT Scanner Radiology Diagnosis Equipment Medical CT Scan Machine for Hospital

SKU: XCT350-CT300 Category: Tags: , , Brand:
Specifications
No. Item Specification
1 Detector
1.1 Detector number 2 pc, full digital, rectangle
1.2 Detector FOV 360mm×500mm
1.3 Photomultiplier 55×2
1.4 Crystal Sodium iodide, thickness: 9.5mm
1.5 Energy range 50keV~400keV
1.6 Inherent energy resolution (99mTc) ≤9.9%
1.7 Inherent space resolution
1.7.1 Central FOV (FWHM) ≤3.5mm
1.7.2 Central FOV (FWTM) ≤6.5mm
1.7.3 Effective FOV (FWHM) ≤3.5mm
1.7.4 Effective FOV (FWTM) ≤6.5mm
1.8 Intrinsic uniformity
1.8.1 Central FOV (differential) ≤2.2%
1.8.2 Central FOV (integral) ≤3.0%
1.8.3 Effective FOV (differential) ≤2.5%
1.8.4 Effective FOV (integral) ≤3.0%
1.9 Inherent lineation
1.9.1 Differential lineation (Central FOV) ≤0.7mm
1.9.2 Differential lineation(effective FOV) ≤1.0mm
1.9.3 Absolute linearity (Central FOV) ≤2.0mm
1.9.4 Absolute linearity (effective FOV) ≤2.0mm
1.1 Maximum count rate (@ window 130 kcps
width 20%)
1.11 System resolution (low energy high ≤8.0mm
collimator)
1.12 System sensitivity (low energy high ≥71cpm/μCi
resolution collimator)
1.13 Planar sensitivity difference between ≤5%
detectors
1.14 System space resolution(low energy high resolution collimator, FWHM)
1.14.1 Axial direction 9.0mm
1.14.2 Agittal direction 12.0mm
1.14.3 Tangential direction 10.0mm
1.15 Detector movement Rotation: 90 º    Up-down: 200mm
1.16 Aver. Rotation center offset ≤2.5mm(low energy general collimator) ≤3mm(low energy high resolution
collimator)
2 Gantry
2.1 Weight(without collimator) ≤2300kg
2.2 Bore ≥64cm
2.3 Rotation
2.3.1 Rotation range ≥225º
From -45 º~180 º
2.3.2 Min. rotation speed ≤0.040RPM
2.3.3 Rotation precision ≤1º
2.4 Position monitor 12″ color screen
2.5 Patient safe belt Yes
2.6 Gantry type None cantilever type
2.7 Control box 1 pc
2.8 Gantry accessories
2.8.1 Supporting structure 1 pc
2.8.2 Turn plate 1 pc
2.8.3 Motion control system 1 set
2.8.4 Power cabinet 1 set
3 Patient table
3.1 Table material Attenuation ≤10%
3.2 Weight capacity 0~135kg
3.3 Scan range ≥190cm
3.4 Position precision ≤2mm
3.5 Vertical movement range 1140mm~650mm
3.6 Horizontal movement
3.6.1 Max. speed ≥30cm/min
3.6.2 Min. speed ≤12cm/min
3.7 Vertical movement speed 20mm/s
3.8 Head support 1 pc
3.9 Table support 1 set
3.1 Motor 2 set
4 Collimator
4.1 Low energy high resolution type collimator (Standard) 2 pc
4.1.1 Low energy high resolution collimator weight ≤35kg per unit
4.2 High energy general type collimator (optional) 2 pc
4.2.1 High energy general type collimator weight ≤75kg/unit
4.3 Low energy general type collimator (optional) 2 pc
4.3.1 Low energy general type collimator weight ≤50kg/unit
4.4 Collimator replacement device 1 pc for each collimator
5 Acquisition workstation
5.1 OS Windows
5.2 CPU ≥2.8GHz
5.3 RAM ≥2GB
5.4 HDD ≥320GB
5.5 Monitor ≥19″
5.6 Recorder CRW/DVD
5.7 Keyboard and mouse 1 pc
5.8 DICOM3.0 Yes
6 Post processing workstation
6.1 OS Windows
6.2 CPU ≥2.8GHz
6.3 RAM ≥2GB
6.4 HDD ≥320GB
6.5 Monitor ≥19″
6.6 Recorder CRW/DVD
6.7 Keyboard and mouse 1 pc
6.8 DICOM3.0 Yes
7 Software function
7.1 Language English
7.1.1 Static collection Yes
7.1.2 Whole body scan acquisition Yes
7.1.3 Dynamic collection Yes
7.1.4 Section Yes
7.2 General image display and analysis Yes
7.2.1 Zoom in, zoom out, copy Yes
7.2.2 Image filter Yes
7.2.3 Cine function Yes
7.2.4 ROI establish, display and statistics Yes
7.2.5 Palette function Yes
7.2.6 Window width/level Yes
7.3 Curve computing software Yes
7.3.1 Time radioactive curve Yes
7.3.2 Image mathematical function Yes
7.3.3 Measurement function Yes
7.4 Organ function analysis
7.4.1 Bone imaging and analysis Yes
7.4.2 Bone sectional imaging analysis Yes
7.4.3 Full body imaging and analysis Yes
7.4.4 Thyroid imaging and analysis Yes
7.4.5 Thyroid sampling and quantitative analysis Yes
7.4.6 General image display and processing function Yes
7.5 Renal function analysis
7.5.1 Basic analysis Yes
7.5.2 Dynamic analysis Yes
7.5.3 Static analysis Yes
7.5.4 GFR glomerular filtration rate analysis Yes
7.5.5 Renal perfusion analysis Yes
7.5.6 Left/right renal clearance rate analysis Yes
7.6 Reconstruction
7.6.1 Transversal reconstruction Yes
7.6.2 Sagittal reconstruction Yes
7.6.3 Coronal reconstruction Yes
7.6.4 Customized cardiac sectional reconstruction Yes
7.7 Report system English
7.7.1 User information management system Yes
7.7.2 Image printing software Yes
7.8 Quality control software English
7.8.1 Pixel size adjustment function Yes
7.8.2 Automatic gain correction function Yes
7.8.3 Energy correction function Yes
7.8.4 Linearity correction function Yes
7.8.5 Uniformity correction function Yes
8 Quality control
8.1 QC phantom Yes
8.2 Source Yes
8.3 User manual Yes
8.4 Free software upgrading Yes

Reviews